SEIMENS AC DRIVES


MICROMASTER 440 – Description

Even in the world of drives, there are often forces which are difficult to control. Until the most powerful of our frequency inverters enters the field. The MICROMASTER 440 has been specially designed for those applications which require broader functionality and a greater dynamic response than is usually the case. The sophisticated vector control system ensures a uniformly high drive quality, even when sudden load changes occur. Fast response inputs and positioning deceleration ramps allow movement to target positions even without an encoder. Due to an integrated brake chopper, it works with outstanding precision, even during braking and short declaration ramps. All this is possible within a power range starting at 0.12 kW (0.16 HP) and going up to 250 kW (350 HP).

MICROMASTER 440 – a brief Summary of its Strengths

  • HMIPlaintext control panels simplify operation and support even exotic languages 
  • Dynamic driving and brakingVarious types of controls and braking facilities
  • CommunicativeVarious communication interfaces ensure usability with the most common network applications 

MICROMASTER 440 – Technical Data

Voltage and power ranges
200-240 V, ± 10%, 1 AC, 0.12 to 3 kW (0.16 to 4 HP)
200-240 V, ± 10%, 0.12 to 45 kW (0.16 to 60 HP)
380-480 V, ± 10%, 0.37 to 250 kW (0.5 to 350 HP)
500-600 V, ± 10%, 0.75 to 90 kW (1.0 to 125 HP)
Types of control
Vector control, FCC (Flux Current Control), multipoint characteristic (parameterizable V/f characteristic), V/f characteristic

MICROMASTER 440 – Typical Uses

Numerous applications in areas such as material handling systems, the textile industry, elevators, hoisting gear, mechanical engineering and the food, beverages and tobacco industries.

MICROMASTER 430Description

Every task performed by a drive system involves its own specific requirements. There is therefore a demand for inverter solutions that can be easily and flexibly adapted to cope with the broadest variety of challenges. It is exactly this flexibility which characterizes our modular MICROMASTER 430. Specially for use with pumps and fans in industry, it performs a wide variety of tasks in similar applications as well. Compared to the MICROMASTER 420, it features greater power efficiency and has more inputs and outputs as well as an optimized operator panel with switch-over between manual and automatic modes of operation.

MICROMASTER 430 – a brief Summary of its Strengths

  • Comprehensive protection Refined motor protection thanks to special PTC/KTY84 input
  • SpecializedIdeal partner for industrial pump & ventilator applications
  • CommunicativeVarious communication interfaces ensure usability with the most common network applications  

MICROMASTER 430 – Technical Data

Voltage and power ranges
380-480 V, ± 10%, 3 AC, 7.5 to 250 kW (10 to 300 HP)
Types of control
FCC (Flux Current Control), multipoint characteristic (parameterizable V/f characteristic), V/f characteristic

MICROMASTER 430 – Typical Uses

Specially suitable for pumps and fans.

MICROMASTER 420 – Description

You need a frequency inverter which can be adapted to your individual requirements without any great effort? No problem for our MICROMASTER 420 – the universal inverter for 3-phase networks and optional field-bus connection. Thanks to its modular design, the extensive standard functions can be supplemented with a wide variety of options. And you do not even need tools, as the operator panels and the communications modules can be simply plugged in. Screwless control terminals – as with the rest of the family – make terminal connection child's play.

MICROMASTER 420 – a brief Summary of its Strengths

  • Compact designBase components such as reactors and filters complement the compact solution
  • VersatileEasy start-up for multiple use
  • CommunicativeVarious communication interfaces ensure usability with the most common network applications

MICROMASTER 420 – Technical Data

Voltage and power ranges
200-240 V, ± 10%, 1 AC, 0.12 to 3 kW (0.16 to 4 HP)
200-240 V, ± 10%, 3 AC, 0.12 to 5.5 kW (0.16 to 7.5 HP)
380-480 V, ± 10%, 3 AC, 0.37 to 11 kW (0.5 to 15 HP)
Types of control
FCC (Flux Current Control), multipoint characteristic (parameterizable V/f characteristic), V/f characteristic
MICROMASTER 420 – Typical Uses
Conveyor systems, material transport, pumps, fans, mechanical engineering.

Friday, February 15, 2013

Omron Inverter-General purpose




Omron Inverters
OMRON Inverters support energy-saving operation of facilities and machines with fine speed control. Models with DeviceNet communications are also provided. Concerning Frequency Inverters, OMRON offers different products in different areas.

Motor Capacity Selection
Before selecting an invertor, first the motor should be chosen.In selecting the motor, first calculate the load inertia for the applications, and then calculate the required capacity and torque.
■Make a simple selection (use Formulas for the required output power)
This method of calculation helps select a motor by calculating the output (W) required by the motor to maintain its regular rotations. It does not include calculation of the effect of acceleration//deceleration. Therefore, make allowance for the calculated value to select a motor. This calculation method can be applied to applications that operate constantly such as fans, conveyers, agitators etc.

















RX,

Customised to your machine

We realise that you need quality and reliability, plus the ability to easily and quickly customise your inverter to the application in hand. And with the RX, you have the perfect tool for the job. Naturally it combines the same high level of quality and performance for which Omron is renowned. It also has abundant application functionality on board and can be customised to match your precise requirements.
  • Up to 132 kW
  • High starting torque in open loop: 200% at 0.3 Hz
  • Full torque at 0 Hz in closed loop
  • Sensor-less and vector closed-loop control
  • Double rating VT 120%/1 min and CT 150%/1 min
  • Built-in EMC filter
  • Built-in logic programmability
  • Built-in application functionality
  • Positioning functionality
  • Automatic energy saving
  • Micro-surge voltage supression
  • Fieldbus communications: Modbus, DeviceNet, 


Force and Flow in Harmony

The new SX inverter is designed to drive high power applications, anything from pumps, fans, compressors or blowers through to closed loop vector control required by cranes, crushers, mills or mixers. The standard inverter has built-in application oriented software and it's hardware design provides flexibility to the user.
  • 500V - 690V power supply from 90kW up to 1000kW
  • 400V power supply from 0.75 kW up to 800 kW
  • Compact design IP54 full range
  • Built-in Filter according to C3 Class
  • Safety according to EN13849-1 and EN62061 standards
  • Load curve control
  • Logic programmability
  • Built-in special application functionality as Multi-pump control or Crane applications
  • Hardware customisation (Main switch, Liquid cooling, 12-pulse rectifier, … )
  • Fieldbus communications: EtherCAT, PROFINET, 




World first three level inverter architecture

The G7 has the world's first 400V 3-level inverter architecture that eliminates or minimises the installation problems associated with IGBT switching (very long cable lengths, bearing currents and common-mode currents) and protects the entire motor-drive system. The G7 can be programmed using DriveWorksEZ™. This is a PC-based, object-orientated, user-friendly, graphical icon programming tool.
  • 3-level control reduces voltage peaks on motor windings by up to 50%. There is no need for an AC reactor on long motor cables.
  • Flux-vector control. Excellent performance in open-loop mode with 150% torque at 0.3Hz.
  • Silent operation. No current de-rating in silent mode (high carrier frequency)
  • Wide selection of option cards: fieldbus, PLC unit, Mechatrolink, analogue and digital I/Os, etc.
  • Programming software: CX-drive for parameter configuration.

High performance vector control

The A1000 provides remarkable advantages through excellent motor drive performance, environmental benefits and energy savings as well as many user orientated operational features. Moreover, the A1000 offers advanced characteristics that are included as standard. In response to the needs of users, we have introduced next-generation product features to A1000 vector control technology.
  • Up to 160 kW
  • PM and IM motor control
  • Powerful torque at 0 Hz, without sensors or feedback devices
  • High-performance current vector control
  • Safety in compliance with EN954-1 safety category 3 stop
  • Programming software: CX-Drive for parameter configuration























Thursday, February 14, 2013

FRENIC5000VG7S Series


FRENIC5000VG7S Series



Features

THE INVERTER
The world's finest inverter. The best control capability. The most requested functions.
  • The industry's best control performance
  • Use with different control types (multi-drive function)
  • A wide range of capacity/flexible applications
  • Built-in user-programmable functions (option as UPAC).
  • Enhanced network readiness
  • Inverter support loader provided
  • Enhanced built-in functions
  • Upgraded maintenance/protective functions
  • Interactive KEYPAD for simple operation
  • Conformity to world standards


Power and Model Variation

• Rated input voltage
Three-phase 200V series 0.75 to 15kW: Three-phase 200 to 230V, 50Hz/60Hz
Three-phase 200V series 18.5 to 90kW: Three-phase 200 to 220V/50Hz, Three-phase 200 to 230V/60Hz
Three-phase 400V series 3.7 to 15kW: Three-phase 380 to 480V, 50Hz/60Hz
Three-phase 400V series 18.5 to 630kW: Three-phase 380 to 440V/50Hz, Three-phase 380 to 480V/60Hz
Three-phase 400Vseries 710 to 800kW: DC 513 to 758V
• Acceptable input power variation
Voltage: +10 to -15%
Frequency: +5 to -5%
Voltage unbalance: 2% or less (conforms to IEC61800-3(5.2.3))
• Capacity range
CT use (for constant torque, overload capability: 150%-1min.)
Three-phase 200V: 0.75 to 90kW
Three-phase 400V: 3.7 to 800kW
VT use (for variable torque, overload capability: 110%-1min.)
Three-phase 200V: 0.75 to 90kW
Three-phase 400V: 3.7 to 630kW
HT use (for vertical transfer application, overload torque: 200%/170%-1sec.)
Three-phase 200V: 3.7 to 55kW
Three-phase 400V: 3.7 to 55kW

Outline Specifications

ItemSpecifications
Control capabilitySpeed control accuracy: ±0.005%
Speed response: 100Hz
Current response: 800Hz
Torque control accuracy (linearity): ±3%
Built-in functionVector control is applicable to two types of motors. Also, V/f control is applicable to the third motor.
Auto-tuning function
Load vibration suppressing observer function
Load adaptive control function
Zero speed lock control
Pulse train input (option)
Orientation control (option)
Built-in PG feedback card
RS485 communications function
I/O terminal checking function
Main circuit capacitor life judgment
Records and displays accumulated operation hour
KeypadCopying function code data function
Remote operation (The extension cable is optional.)
Display in seven languages
JOG (jogging) operation
Remote/local selection
Braking unitThree-phase 200V: 55kW or less (built-in), 75kW or more (option)
Three-phase 400V: 110kW or less (built-in), 132kW or more (option)
I/O terminal points
InputOutput
Analog3 point4 point
Digital11 point5 point
EnclosureUp to 15kW: IP20 (closed type), 18.5kW or over: IP00 (open type), IP20 (closed type) is optional.

@manual pdf.










ABB General purpose drive, ACS550-01


 ABB General purpose drive, ACS550-01


ABB general purpose drives are designed to control a wide range of applications. They are easy to select, install, commission and use, and provide many built-in features. ABB general purpose drives are widely available through our logistical and technical partners.

Wall-mounted units 

Power range:
 
0.75 to 75 kW (0.8 to 100 hp)
0.75 to 160 kW (0.5 to 200 hp)

Supply voltage:
 
3-phase, 208 to 240 V +10% /-15%
3-phase, 380 to 480 V +10% /-15%
ABB general purpose drives can be used in a wide range of industries. Typical applications include pump, fan and constant torque use, such as conveyors. ABB general purpose drives are ideal in those situations where there is a need for simplicity to install, commission and use and where customizing or special product engineering is not required. The drives include several features as standard, such as swinging choke, EMC filter and control panel. All drives are tested with full load at the factory ensuring premium quality.
To view technical data of the products, please click on the Data tab above.

Highlights
− Energy efficiency counters
− Intuitive use with assistant control panel
− Swinging choke for superior harmonic reduction
− Vector control
− Coated boards for harsh environments
− Built-in category C2 EMC filter (1st environment) as standard
− Flexible field bus system with built-in Mod-bus and numerous internally mountable field bus adapters
− Brake chopper as standard in the frames R1 and R2
− Flash-Drop tool for cold configuration
 

Tuesday, February 12, 2013

TECO INVERTER -7300CV


TECO 7300CV AC Drive, 7.5 HP, 460V 3 PH Input, 460V 3 PH Output, 13.0FLA, IP20, Frame 3 (JNTHBCBA7R50BE-U)
















  • 380-460VAC 3 PH, 50/60Hz (Voltage +10% to -10%, Frequency ±5%) Input
  • Sensorless Vector & V/Hz control modes
  • Integrated PLC Functions
  • Built-in PID Control 
  • 0-460V, 3 PH Output
  • 1 Analog Input (0-10V, 4-20mA, 0-20mA)
  • 1 Programmable Multi-function Analog Input (0-10V)
  • 7 Programmable Multi-function Digital Inputs
  • 1 Analog Output (0-10VDC)
  • 2 Multi-function Output Relay
  • Removable Keypad with Potentiometer
  • 4 digit, 7 segment LED display
  • 150% rated current for 1 minute
  • 200% instantaneous overcurrent
  • Electronic overload protection and stall prevention
  • Ground fault and short circuit protection
  • UL 508 / cUL / CE
  • 2 year warranty